| OUTPUT |
|---|
| Output Volt Amp Capacity (VA) | 500 |
|---|
| Output Watt Capacity (Watts) | 300 |
|---|
| Power Factor | 0.6 |
|---|
| Nominal Output Voltage(s) Supported | 220V 230V 240V |
|---|
| Nominal Voltage Details | 230v nominal inverter output voltage |
|---|
| Frequency Compatibility | 50 / 60 Hz |
|---|
| Frequency Compatibility Details | Automatic frequency selection |
|---|
| Output Voltage Regulation (Line Mode) | -8%, +15% |
|---|
| Output Voltage Regulation (Battery Mode) | +/- 5% |
|---|
| Output Receptacles | (7) C13 |
|---|
| Included Output Power Cables | Two 1.8m IEC320-C13 to C14 load jumper cables |
|---|
| UPS Output Receptacles (Surge Suppression Only) | 6 UPS outlets, 1 surge-only outlet |
|---|
| Load Management Receptacles | One switchable single-outlet C13 load bank |
|---|
| Hot-Swap PDU options | PDUBHV10 (2U / 8 C13 outlets) |
|---|
| Output AC Waveform (AC Mode) | Sine wave |
|---|
| Output AC Waveform (Battery Mode) | PWM sine wave |
|---|
| Individually Controllable Load Banks | No |
|---|
| INPUT |
|---|
| Rated input current (Maximum Load) | 2.4A |
|---|
| Nominal Input Voltage(s) Supported | 230V AC |
|---|
| UPS Input Connection Type | C14 inlet |
|---|
| UPS Input Connection Description | C14 inlet accepts user-supplied AC power cord with country-specific plug |
|---|
| Input Circuit Breakers | 8A |
|---|
| Input Phase | Single-Phase |
|---|
| BATTERY |
|---|
| Full Load Runtime (min.) | 3.2 min. (300w) |
|---|
| Half Load Runtime (min.) | 14.6 min. (150w) |
|---|
| DC System Voltage (VDC) | 12 |
|---|
| Battery Recharge Rate (Included Batteries) | Less than 4 hours from 10% to 90% (typical, full load discharge) |
|---|
| Internal UPS Replacement Battery Cartridge | RBC62-1U |
|---|
| Battery Access | Battery access door |
|---|
| Battery Replacement Description | Hot-swappable, user replaceable batteries |
|---|
| Expandable Runtime | No |
|---|
| VOLTAGE REGULATION |
|---|
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 187 |
|---|
| Undervoltage Correction | Input voltages between 187 and 215 are boosted by 14% |
|---|
| USER INTERFACE, ALERTS AND CONTROLS |
|---|
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
|---|
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch once silenced, alarm will re-sound to indicate low-battery status |
|---|
| Audible Alarm | Audible alarm indicates power-failure, overload and low-battery conditions |
|---|
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
|---|
| SURGE / NOISE SUPPRESSION |
|---|
| UPS AC Suppression Joule Rating | 480 |
|---|
| EMI / RFI AC Noise Suppression | Yes |
|---|
| PHYSICAL |
|---|
| Included Mounting Accessory Description | Included mounting flanges support rackmount installation in 2 or 4 post racks |
|---|
| Primary Form Factor | Rackmount |
|---|
| UPS Power Module Dimensions (hwd, in.) | 1.73 x 17.32 x 11.61 |
|---|
| Rack Height (U Spaces) | 1 |
|---|
| Minimum Required Rack Depth (inches) | 13.86 |
|---|
| UPS Housing Material | Steel |
|---|
| Primary UPS Height (mm) | 44 |
|---|
| Primary UPS Width (mm) | 440 |
|---|
| Primary UPS Depth (mm) | 295 |
|---|
| COMMUNICATIONS |
|---|
| Communications Interface | USB (HID enabled) DB9 Serial EPO (emergency power off) Slot for SNMP/Web interface |
|---|
| Network Management Cards | SNMPWEBCARD TLNETCARD WEBCARDLX |
|---|
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
|---|
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
|---|
| Communications Cable | USB and DB9 cabling included |
|---|
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|---|
| Network UPS Tools Compatibility | NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at networkupstools.org/stable-hcl |
|---|
| LINE / BATTERY TRANSFER |
|---|
| Transfer Time | 2-4 milliseconds |
|---|
| Low Voltage Transfer to Battery Power (Setpoint) | 187 |
|---|
| High Voltage Transfer to Battery Power (Setpoint) | 264 |
|---|
| SPECIAL FEATURES |
|---|
| Grounding Lug | Back panel grounding lug |
|---|
| High Availability UPS Features | Hot swappable batteries |
|---|
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS Individually controllable load banks |
|---|
| CERTIFICATIONS |
|---|
| UPS Certifications | Additional certifications CE ROHS (Restriction of Hazardous Substances) Tested to EAC (Belarus, Kazakhstan, Russia) |
|---|
| UPS Certification Details | LVD 2014/35/EU EMC 2014/30/EU EN 62040-1: 2008+A1: 2013 EN 62040-2: 2006+AC: 2006 |
|---|
| Item Dimension (L"xW"xH") | 5 x 16 x 22 |
|---|
| Weight | 20.8 lbs |
|---|
| Warranty Information | 2-year limited warranty |
|---|