OUTPUT : Output Volt Amp Capacity (VA) : 6000 Output kVA capacity (kVA): 6.0 Output Watt Capacity (watts): 5400 Output kW capacity: 5.4 Output power factor: 0.9 Crest Factor : 3:1 Nominal Output Voltage(s) Supported: 200V 208V 220V 230V 240V Frequency compatibility: 50/60 Hz (auto-selectable) Frequency compatibility details: Output frequency matches input nominal on startup Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating) Output voltage regulation (line mode): +/- 2% Output voltage regulation (Economy line mode): +/- 10% Output voltage regulation (Battery mode) : +/- 2% Built-in UPS output receptacles : Hardwire Output receptacle details : Hardwire input and output connections are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement Output AC waveform (AC mode) : Pure Sine wave Output AC waveform (battery mode): Pure Sine wave INPUT : Rated input current (at maximum load) : 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V) Nominal Input Voltage(s) Supported : 200V AC 208V AC 220V AC 230V AC 240V AC UPS input connection type: Hardwire BATTERY : Full load runtime (minutes) : 2 minutes (5400 watts) Half load runtime (minutes): 8.5 minutes (2700 watts) Expandable battery runtime: Runtime is expandable with external battery packs External battery pack compatibility: BP192V12-3U DC system voltage (VDC): 192 Battery recharge rate (included batteries) : 6 hours from 10% to 90% (internal batteries) Replacement battery cartridge (internal UPS battery replacement): RBC5-192 Battery Access : Front panel battery access door Battery replacement description : Hot-swappable, user replaceable internal batteries LEDS ALARMS SWITCHES : LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status LCD screen offers additional information and control options Alarms : Unique audible alarms for all major UPS, environmental and power conditions (see manual) Alarm cancel operation : Alarm cancel switch Switches : Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads SURGE / NOISE SUPPRESSION: UPS AC suppression response time: Instantaneous EMI / RFI AC noise suppression : Yes PHYSICAL : Installation form factors supported with included accessories : 4 post 19 inch rackmount (mounting kit included) Installation form factors supported with optional accessories : 2 post rackmount (2POSTRMKITHD) Tower (2-9USTAND) Primary form factor: Rackmount Installed whole system total rack space height (rack spaces): 4U UPS housing material : Steel Cooling method: Fans COMMUNICATIONS: Communications interface : USB (HID enabled) DB9 Serial EPO (emergency power off) Slot for SNMP/Web interface Network monitoring port description : Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports PowerAlert software: Included Communications cable: USB, DB9 serial and EPO cables included WatchDog compatibility: Yes LINE / BATTERY TRANSFER : Transfer time : No transfer time (0 ms.) in online, double-conversion mode Transfer time (economy mode) : 8 ms. typical power failure response in optional economy mode Low voltage transfer to battery power (setpoint): 156V (full load) / 100V (50% load or less, derates linearly) High voltage transfer to battery power (setpoint) : 280V (full load) / 300V (90% load or less) SPECIAL FEATURES : Cold Start (startup in battery mode during a power failure): Cold-start operation supported High availability UPS features: Automatic inverter bypass Manual bypass switch Detachable hot-swap PDU Hot swappable UPS power module Hot swappable batteries Green high efficiency features : High efficiency economy mode operation Support for daily startup and shutoff Schedulable daily hours of economy mode operation CERTIFICATIONS: UPS Certifications : Tested to UL1778 (USA) Tested to CSA (Canada) Meets FCC Part 15 Category A (EMI) ROHS (Restriction of Hazardous Substances) UPS Certification details: IEC 61000-4-5 1995 B Surge Immunity Weight : 156.50 lb