Output: Output Volt Amp Capacity (VA): 2200 Output kVA Capacity (kVA): 2.2 Output Watt Capacity (Watts): 1600 Output kW Capacity (kW): 1.6 Power Factor: 0.7 Nominal Output Voltage(s) Supported: 120V Frequency Compatibility: 60 Hz Output Voltage Regulation (Line Model): -18% / +8% Output Voltage Regulation (Battery Mode): +/-5% Output Receptacles: (6) 5-15/20R, (1) L5-20R Output AC Waveform (AC Mode): Sine Wave Output AC Waveform (Battery Mode): Pure Sine Wave Input: Rated Input Current (Maximum Load): 14.8A Nominal Input Voltage(s) Supported: 120V AC UPS Input Connection Type: 5-20P Input Circuit Breakers: 20A UPS Input Cord Length (ft): 10 Recommended Electrical Service: 20A 120V Input Phase: Single Phase Battery: Full Load Runtime (min): 5 min (1600W) Half Load Runtime (min): 13 min (800W) DC System Voltage (VDC): 48 Battery Recharge Rate (Included Batteries): Less than 4.5 hours from 10% to 90% (Typical, Full Load Discharge) Internal UPS Replacement Battery Cartridge: RBC54 Battery Access: Battery Access Door Battery Replacement Description: Hot-Swappable, User Replacement Batteries Expandable Runtime: No Voltage Regulation: Voltage Regulation Description: Automatic Voltage Regulation (AVR) maintains line power operation with an input voltage range of 83V to overvoltage of 145V Overvoltage Correction: Input voltages between 127 and 145 are reduced by 12% Undervoltage Correction: Input voltages between 96 and 108V are boosted by 12% Severe Undervoltage Correction: Input voltages between 83 and 95V are reduced by 24% User Interface, Alerts and Controls: Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch Audible Alarm: Audible alarm indicates power failure and overload conditions LED Indicators: 9 LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level Surge/Noise Suppression: UPS AC Suppression Joule Rating: 570 UPS AC Suppression Response Time: Instantaneous EMI/RFI AC Noise Suppression: Yes Physical: Primary Form Factor: Tower Cooling Method: Fan UPS Housing Material: Steel Environmental Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity: 0 to 95%, non-condensing AC Mode BTU / HR. (Full Load): 286.3 Battery Mode BTU / HR. (Full Load): 885.6 AC Mode Efficiency Rating (100% Load): 95% Audible Noise: Audible Noise <50 dBA at Front Side 1 Meter Communications: Communications Interface: USB DB9 Serial EPO (emergency power off) Slot for SNMP/Web interface Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions PowerAlert Software: Included Communications Cable: USB and DB9 Cabling Included WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications Line/Battery Transfer Transfer Time: 2-4 Milliseconds Low Voltage Transfer to Battery Power (Setpoint): 83 High Voltage Transfer to Battery Power (Setpoint): 145 Special Features Cold Start (Startup in Battery Mode During a Power Failure): Cold-Start Operation Supported High Availability UPS Features: Hot Swappable Batteries Green Energy Saving Features: Greater than 95% Efficiency, GREEN UPS Certifications UPS Certifications: Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Meets FCC Part 15 Category A (EMI) Item Dimension (L"xW"xH") 15 x 14 x 18