| Output | |
|---|---|
| Output Volt Amp Capacity (VA) | 2200 |
| Output kVA Capacity (kVA) | 2.2 |
| Output Watt Capacity (Watts) | 1600 |
| Output kW Capacity (kW) | 1.6 |
| Power Factor | 0.7 |
| Nominal Output Voltage(s) Supported | 120V |
| Frequency Compatibility | 60 Hz |
| Output Voltage Regulation (Line Model) | -18% / +8% |
| Output Voltage Regulation (Battery Mode) | +/-5% |
| Output Receptacles | (6) 5-15/20R, (1) L5-20R |
| Output AC Waveform (AC Mode) | Sine Wave |
| Output AC Waveform (Battery Mode) | Pure Sine Wave |
| Input | |
| Rated Input Current (Maximum Load) | 14.8A |
| Nominal Input Voltage(s) Supported | 120V AC |
| UPS Input Connection Type | 5-20P |
| Input Circuit Breakers | 20A |
| UPS Input Cord Length (ft) | 10 |
| Recommended Electrical Service | 20A 120V |
| Input Phase | Single Phase |
| Battery | |
| Full Load Runtime (min) | 5 min (1600W) |
| Half Load Runtime (min) | 13 min (800W) |
| DC System Voltage (VDC) | 48 |
| Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% (Typical, Full Load Discharge) |
| Internal UPS Replacement Battery Cartridge | RBC54 |
| Battery Access | Battery Access Door |
| Battery Replacement Description | Hot-Swappable, User Replacement Batteries |
| Expandable Runtime | No |
| Voltage Regulation | |
| Voltage Regulation Description | Automatic Voltage Regulation (AVR) maintains line power operation with an input voltage range of 83V to overvoltage of 145V |
| Overvoltage Correction | Input voltages between 127 and 145 are reduced by 12% |
| Undervoltage Correction | Input voltages between 96 and 108V are boosted by 12% |
| Severe Undervoltage Correction | Input voltages between 83 and 95V are reduced by 24% |
| User Interface, Alerts and Controls | |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch |
| Audible Alarm | Audible alarm indicates power failure and overload conditions |
| LED Indicators | 9 LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level |
| UPS AC Suppression Joule Rating | 570 |
| UPS AC Suppression Response Time | Instantaneous |
| EMI/RFI AC Noise Suppression | Yes |
| Physical | |
| Primary Form Factor | Tower |
| Cooling Method | Fan |
| UPS Housing Material | Steel |
| Environmental | |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity | 0 to 95%, non-condensing |
| AC Mode BTU / HR. (Full Load) | 286.3 |
| Battery Mode BTU / HR. (Full Load) | 885.6 |
| AC Mode Efficiency Rating (100% Load) | 95% |
| Audible Noise | Audible Noise <50 dBA at Front Side 1 Meter |
| Communications | |
| Communications Interface | USB DB9 Serial EPO (emergency power off) Slot for SNMP/Web interface |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | Included |
| Communications Cable | USB and DB9 Cabling Included |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Line/Battery Transfer | |
| Transfer Time | 2-4 Milliseconds |
| Low Voltage Transfer to Battery Power (Setpoint) | 83 |
| High Voltage Transfer to Battery Power (Setpoint) | 145 |
| Special Features | Cold Start (Startup in Battery Mode During a Power Failure): Cold-Start Operation Supported |
| High Availability UPS Features | Hot Swappable Batteries |
| Green Energy Saving Features | Greater than 95% Efficiency, GREEN UPS |
| Certifications | |
| UPS Certifications | Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Meets FCC Part 15 Category A (EMI) |
| Item Dimension (L"xW"xH") | 15 x 14 x 18 |
| Weight | 57.00 lb |
| Warranty Information | 2 Years |