TK001-SYS-5039MS-H12TRF - Supermicro System TK001-SYS-5039MS-H12TRF 12xE3-1230V6 4x16GB Brown Box
Technical Specifications
Motherboard
Motherboard MBD-X11SSE-F
Processor/Cache
CPU Single Socket H4 (LGA 1151) supports: Intel Xeon processor E3-1200 v6/v5, Intel 7th/6th Gen Core i3, Intel Pentium, Intel Celeron processors CPU TDP up to 80W System Memory (per node)
Chipset Intel C236 chipset SATA SATA3 (6Gbps) via C236 controller IPMI Support for Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM over LAN support ASPEED AST2400 BMC Headers 1 Type A USB 3.0 Graphics ASPEED AST2400 Graphics (BMC with Graphic controller) Network Devices (per node)
SATA 2 SATA3 (6Gbps) ports LAN 2 RJ45 Gigabit Ethernet LAN ports DOM SATA DOM (Disk on Module) power connector support KVM 1 VGA, 1 COM and 2 USB 2.0 (with KVM dongle) System BIOS
BIOS Type 128Mb SPI Flash EEPROM with AMI BIOS BIOS Features DMI 2.3 ACPI 1.0 / 2.0 USB Keyboard support SMBIOS 2.3 Front Window (each node)
Switch Power / UID Chassis
Form Factor 3U Model CSE-939HS-R2K04B Color Black Drive Bays (per node)
Internal 2x 3.5 inch SATA3 OR 4x 2.5 inch SATA3 HDDs OR 2x 2.5 inch NVMe + 1x 3.5 inch SATA3 OR 2x 2.5 inch NVMe + 2x 2.5 inch SATA3 up to 48x 2.5 inch drives total Enterprise SATA HDD only recommended System Cooling
Fans 4 Heavy duty 9cm fans with optimal cooling zone Power Supply with Digital Switching Control 2000W Titanium Level (96%) High-efficiency Redundant Power Supplies Total Output Power 1000W/1800W/1980W/2000W AC Input 100-127 V, 50-60 Hz 200-220 V, 50-60 Hz 220-230 V, 50-60 Hz 230-240 V, 50-60 Hz +12V Max: 83.3A and Min: 0A (100Vac-127Vac) Max: 150A and Min: 0A (200Vac-220Vac) Max: 165A and Min: 0A (220Vac-230Vac) Max: 166.7A and Min: 0A (230Vac-240Vac) 5V SB Max: 1A / Min: 0A PC Health Monitoring
CPU Monitors for CPU Cores, +3.3V, +5V, +12V, +3.3V Standby, +5V Standby, VBAT, Memory, Chipset Voltages 3-Phase-switching voltage regulator with auto-sense from 0.5V-2.3V FAN Cooling zone Temperature Monitoring for CPU and chassis environment Operating Environment / Compliance
RoHS RoHS Compliant Environmental Spec Operating Temperature: 10oC to 35oC (50oF to 95oF) Non-operating Temperature: -40oC to 70oC (-40oF to 158oF) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) Item Dimension (L inchxW inchxH inch) NA
Weight 130lb
Warranty Information 3 year parts, 1 year labor, 1 year limited cross ship warranty