General InformationTripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in a variety of application environments. Online, double-conversion Uninterruptible Power Supply / UPS maintains perfectly regulated output power by continuously converting raw AC input to DC, then re-converting output back to AC. Sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Battery independent restart. Field-replaceable, hot-swappable internal batteries and external battery packs.Technical InformationPlug/Connector Type: NEMA L5-30PReceptacles: 8 x NEMA 5-15/20RReceptacles: 1 x NEMA L5-30RBypass Switch: AutomaticEmergency Power OFF: YesTransfer Time: 0 nsPower DescriptionLoad Capacity: 3000 VA/2700 WInput Voltage: 100 V ACInput Voltage: 110 V ACInput Voltage: 115 V ACInput Voltage: 120 V ACInput Voltage: 127 V ACOutput Voltage: 100 V ACOutput Voltage: 110 V ACOutput Voltage: 115 V ACOutput Voltage: 120 V ACOutput Voltage: 127 V ACManagementNetwork Management: SNMP ManageableInterfaces/PortsSerial Port: YesUSB: YesBattery InformationBackup/Run Time (Full Load): 4.10 MinuteBackup/Run Time (Half Load): 13.20 MinuteTypical Battery Recharge Time: 3 HourHot Swappable: YesPhysical CharacteristicsHeight: 10.2"Width: 9"Depth: 19.5"Form Factor: TowerMiscellaneousPackage Contents: SmartOnline SU3000XLCD 3000VA Tower UPSPoweralert Software CDOwner's Manual with Warranty InformationEPO (Emergency Power Off) CableUSB CableDB9 CableCertifications & Standards: UL1778CSANOMFCC Part 15Software Included: PowerAlert SoftwareWarrantyLimited Warranty: 2 Year
Technical Specifications
OUTPUT Output Volt Amp Capacity (VA) 3000 Output kVA capacity (kVA) 3.0 Output Watt Capacity (watts) 2700 Output power factor 0.9 Crest Factor 3:1 Nominal Output Voltage(s) Supported 100V 110V 120V 127V Nominal Voltage details 120V default Frequency compatibility 50 / 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion Output voltage regulation (line mode) +/- 2% Output voltage regulation (Economy line mode) +/- 10% Output voltage regulation (Battery mode) +/- 3% Built-in UPS output receptacles 8 5-15/20R outlet(s) 1 L5-30R outlet(s) Built-in controllable switched load banks Two switchable four-outlet load banks Output AC waveform (AC mode) Pure Sine wave Output AC waveform (battery mode) Pure Sine wave INPUT Rated input current (at maximum load) 24A Nominal Input Voltage(s) Supported 100V AC 110V AC 120V AC 127V AC Nominal input voltage description 120V factory default UPS input connection type L5-30P Input circuit breaker 40A UPS Input cord length (ft.) 10 UPS Input cord length (m) 3 Recommended Electrical Service 30A 120V BATTERY Full load runtime (minutes) 4.1 min. (2700w) Half load runtime (minutes) 13.2 min. (1350w) Expandable battery runtime Extended runtime supported via optional external battery packs External battery pack compatibility BP72V15-2U (limit 1) BP72V28RT-3U (multi-pack compatible) Expandable runtime description External battery configurations require the use of Tripp Lites External Battery Configuration Software, see manual for details DC system voltage (VDC) 72 Battery recharge rate (included batteries) Less than 3 hours from 10% to 90% Replacement battery cartridge (internal UPS battery replacement) RBC96-3U Battery Access Battery access door Battery replacement descriptionHot-swappable, user replaceable batteries VOLTAGE REGULATION Voltage regulation description Online, double-conversion power conditioning Overvoltage correction 2% output voltage regulation during overvoltages to 150 Undervoltage correction 2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load) SURGE / NOISE SUPPRESSION UPS AC suppression joule rating 570 UPS AC suppression response time Instantaneous UPS Dataline suppression 1 line TEL/DSL (1 in / 1 out) 10/100Base T Ethernet EMI / RFI AC noise suppression Yes PHYSICAL Cooling method Fan UPS housing material Steel CERTIFICATIONS UPS Certifications Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Meets FCC Part 15 Category A (EMI) Weight 76.00 Item Dimension 15.2 x 13 x 24 Warranty Information 2-year limited warranty