Trust the Tripp Lite SmartPro UPS XL 1500 to protect your server from power outages. This intelligent, line interactive UPS system also keeps your networking accessories and telecommunications equipment working through blackouts. Large internal batteries offer the XL 1500 UPS 20 minutes of half load run.
Technical Specifications
OUTPUT Output Volt Amp Capacity (VA) :1500 Output kVA capacity (kVA) :1.5 Output Watt Capacity (watts) :980 Output power factor :0.7 Nominal Output Voltage(s) Supported :120V Frequency compatibility :60 Hz Output voltage regulation (line mode) :-18%, +8% Output voltage regulation (Battery mode) :+/- 5% Built-in UPS output receptacles :6 5-15R outlet(s) Built-in controllable switched load banks :One switchable single-outlet 5-15R load bank Output AC waveform (AC mode) :Sine wave Output AC waveform (battery mode) :PWM sine wave INPUT Rated input current (at maximum load) :12A Nominal Input Voltage(s) Supported :120V AC UPS input connection type :5-15P Input circuit breaker :15A UPS Input cord length (ft.) :6 UPS Input cord length (m) :1.8 Recommended Electrical Service :15A 120V BATTERY Full load runtime (minutes) :7 min. (980w) Half load runtime (minutes) :20 min. (490w) Expandable battery runtime :Extended runtime supported via optional external battery packs External battery pack compatibility :BP36V15-2U (limit 1) BP36V42-3U (multi-pack compatible) DC system voltage (VDC) :36 Battery recharge rate (included batteries) :Less than 4 hours from 10% to 90% Replacement battery cartridge (internal UPS battery replacement) :RBC53 Battery Access :Battery access door Battery replacement description :Hot-swappable, user replaceable batteries VOLTAGE REGULATION Voltage regulation description :Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 Overvoltage correction :Input voltages between 128 and 147 are reduced by 12% Undervoltage correction :Input voltages between 93 and 107 are boosted by 14% Severe undervoltage correction :Input voltages between 75 and 92 are boosted by 30% LEDS ALARMS and SWITCHES LED Indicators :5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status Alarms :Audible alarm indicates power-failure, overload and low-battery conditions Alarm cancel operation :Power-fail alarm can be silenced using alarm-cancel switch once silenced, alarm will re-sound to indicate low-battery status Switches :2 Switches control off/on power status and alarm-cancel/self-test operation SURGE / NOISE SUPPRESSION UPS AC suppression joule rating :480 UPS AC suppression response time :Instantaneous EMI / RFI AC noise suppression :Yes
PHYSICAL Installation form factors supported with included accessories :Tower Installation form factors supported with optional accessories :Wallmount (UPSWM - tower mounting kit) Primary form factor :Tower UPS housing material :PVC Cooling method :Fan COMMUNICATIONS Communications interface :USB DB9 Serial Network monitoring port description :Supports detailed monitoring of UPS and site power conditions PowerAlert software :Included Communications cable :USB and DB9 cabling included WatchDog compatibility :Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer time :2-4 milliseconds Low voltage transfer to battery power (setpoint) :75 High voltage transfer to battery power (setpoint) :147
SPECIAL FEATURES Cold Start (startup in battery mode during a power failure) :Cold-start operation supported High availability UPS features :Hot swappable batteries Green high efficiency features :Greater than 95% efficiency - GREEN UPS Individually controllable load banks
CERTIFICATIONS UPS Certifications :Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Meets FCC Part 15 Category A (EMI) Item Dimension (L"xW"xH"): 18 x 12 x 13.5