| OUTPUT | |
|---|---|
| Output Volt Amp Capacity (VA) | 1500 |
| Output kVA capacity (kVA) | 1.5 |
| Output Watt Capacity (watts) | 980 |
| Output power factor | 0.7 |
| Nominal Output Voltage(s) Supported | 120V |
| Frequency compatibility | 60 Hz |
| Output voltage regulation (line mode) | -18%, +8% |
| Output voltage regulation (Battery mode) | +/- 5% |
| Built-in UPS output receptacles | 6 5-15R outlet(s) |
| Built-in controllable switched load banks | One switchable single-outlet 5-15R load bank |
| Output AC waveform (AC mode) | Sine wave |
| Output AC waveform (battery mode) | PWM sine wave |
| INPUT | |
| Rated input current (at maximum load) | 12A |
| Nominal Input Voltage(s) Supported | 120V AC |
| UPS input connection type | 5-15P |
| Input circuit breaker | 15A |
| UPS Input cord length (ft.) | 6 |
| UPS Input cord length (m) | 1.8 |
| Recommended Electrical Service | 15A 120V |
| BATTERY | |
| Full load runtime (minutes) | 7 min. (980w) |
| Half load runtime (minutes) | 20 min. (490w) |
| Expandable battery runtime | Extended runtime supported via optional external battery packs |
| External battery pack compatibility | BP36V15-2U (limit 1) BP36V42-3U (multi-pack compatible) |
| DC system voltage (VDC) | 36 |
| Battery recharge rate (included batteries) | Less than 4 hours from 10% to 90% |
| Battery Access | Battery access door |
| Battery replacement description | Hot-swappable, user replaceable batteries |
| VOLTAGE REGULATION | |
| Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
| Overvoltage correction | Input voltages between 128 and 147 are reduced by 12% |
| Undervoltage correction | Input voltages between 93 and 107 are boosted by 14% |
| Severe undervoltage correction | Input voltages between 75 and 92 are boosted by 30% |
| LEDS ALARMS and SWITCHES | |
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
| Alarms | Audible alarm indicates power-failure, overload and low-battery conditions |
| Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch once silenced, alarm will re-sound to indicate low-battery status |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| SURGE / NOISE SUPPRESSION | |
| UPS AC suppression joule rating | 480 |
| UPS AC suppression response time | Instantaneous |
| EMI / RFI AC noise suppression | Yes |
| PHYSICAL | Installation form factors supported with included accessories :Tower |
| Primary form factor | Tower |
| UPS housing material | PVC |
| Cooling method | Fan |
| COMMUNICATIONS | |
| Communications interface | USB DB9 Serial |
| Network monitoring port description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert software | Included |
| Communications cable | USB and DB9 cabling included |
| WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| LINE / BATTERY TRANSFER | |
| Transfer time | 2-4 milliseconds |
| Low voltage transfer to battery power (setpoint) | 75 |
| High voltage transfer to battery power (setpoint) | 147 |
| SPECIAL FEATURES | Cold Start (startup in battery mode during a power failure) :Cold-start operation supported |
| High availability UPS features | Hot swappable batteries |
| Green high efficiency features | Greater than 95% efficiency - GREEN UPS Individually controllable load banks |
| CERTIFICATIONS | |
| UPS Certifications | Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Meets FCC Part 15 Category A (EMI) |
| Item Dimension (L"xW"xH") | 18 x 12 x 13.5 |
| Weight | 46.0 lb |
| Warranty Information | 2 Years |