Received! Our sales team will contact you soon.

Tripp SU750RTXLCD2U Ups Smart Online 750va 675w Rackmount 100v-120v Lcd Usb Db9 2urm Rt - 750 Va-675 W - 127 V Ac, 127 V Ac - 4.30 Minute Stand-by Time - 2u Tower-rack Mountable - 6 X Nema 5-15r

Make an offer


Out of Stock

Special Price $811.70 Regular Price $1095.80

Condition: New
Tripp Lite
Free Shipping TRIPP LITE

Technical InformationPlug/Connector Type: NEMA 5-15PReceptacles: 6 x NEMA 5-15RBypass Switch: AutomaticEmergency Power OFF: YesTransfer Time: 0 nsPower DescriptionLoad Capacity: 750 VA/675 WInput Voltage: 110 V ACOutput Voltage: 127 V AC, 110 V AC, 120 V ACManagementNetwork Management: SNMP ManageableInterfaces/PortsSerial Port: YesUSB: YesBattery InformationBackup/Run Time (Full Load): 4.30 MinuteBackup/Run Time (Half Load): 13.90 MinuteTypical Battery Recharge Time: 3 HourHot Swappable: YesPhysical CharacteristicsHeight: 3.5"Width: 17.5"Depth: 12.5"Rack Height: 2UForm Factor: Rack/TowerWeight (Approximate): 27.60 lbMiscellaneousPackage Contents: SU750RTXLCD2U UPS SystemPowerAlert Software CDUSB CableSerial CableEPO Cable4 Post Rackmount Installation KitInstruction ManualCertifications & Standards: UL1778 (USA)CSA (Canada)FCC Part 15 Category B (EMI)Software Included: PowerAlert UPS Monitoring SoftwareEnvironmentally Friendly: YesEnvironmental Certification: RoHSWarrantyLimited Warranty: 2 Year


OUTPUT
Output Volt Amp Capacity (VA)
750
Output kVA Capacity (kVA)
.75
Output Watt Capacity (Watts)
675
Output Capacity Details
ON LINE MODE: Maximum output capacity is reduced to 608 watts at 100V nominal FREQUENCY CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120/115/110V: 472 watts / 100V: 425 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
Power Factor
0.9
Crest Factor
3:1
Nominal Output Voltage(s) Supported
100V 110V 115V 120V 127V
Nominal Voltage Details
120V factory-default nominal voltage
Frequency Compatibility
50 / 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details
ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup Output matches input frequency when +/-5Hz of nominal Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz.
Output Voltage Regulation (Line Mode)
+/- 2%
Output Voltage Regulation (Economy Line Mode)
+/- 10%
Output Voltage Regulation (Battery Mode)
+/- 3%
Output Receptacles
(6) 5-15R
Load Management Receptacles
Two switchable single-outlet 5-15R l INPUT
Rated input current (Maximum Load)
8A
Nominal Input Voltage(s) Supported
100V AC 110V AC 115V AC 120V AC 127V AC
Nominal Input Voltage Description
120V factory default
UPS Input Connection Type
5-15P
Input Circuit Breakers
15A
UPS Input Cord Length (ft.)
10
UPS Input Cord Length (m)
3.0
Recommended Electrical Service
15A 120V
Input Phase
Single-Phase

BATTERY
Full Load Runtime (min.)
4.3 min. (675w)
Half Load Runtime (min.)
13.9 min. (337.5w)
Expandable Battery Runtime
Extended runtime supported via optional external battery packs
External Battery Pack Compatibility
BP24V15RT2U(limit 1) BP24V28-2U(limit 1) BP24V70-3U(multi-pack compatible) BP24V36-2US(multi-pack compatible)
Expandable Runtime Description
Some external battery configurations require the use of Tripp Lites External Battery Configuration Software, see manual for details
DC System Voltage (VDC)
24
Battery Recharge Rate (Included Batteries)
Less than 3 hours recharge to 90% (typical, full load discharge)
Internal UPS Replacement Battery Cartridge
RBC24V-LCD
Battery Access
Front panel battery access
Battery Replacement Description
Hot-swappable, user replaceable batteries
Expandable Runtime
Yes

VOLTAGE REGULATION
Voltage Regulation Description
Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages
Overvoltage Correction
Corrects overvoltages to 150V (0-100% load)
Undervoltage Correction
Corrects undervoltages to 100V at full load (90V at 100V nominal)
Severe Undervoltage Correction
Corrects brownouts to 70V (70% load) 55V (33% load)

USER INTERFACE, ALERTS CONTROLS
Front Panel LCD Display
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
Switches
2 switches control off/on power status and alarm-cancel operation 2 additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options
Alarm Cancel Operation
Power-fail alarm can be temporarily silenced using alarm-cancel switch silent mode alarm configuration option available
Audible Alarm
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
LED Indicators
7 front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status

SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
570
UPS AC Suppression Response Time
Instantaneous
UPS Dataline Suppression
1 line TEL/DSL (1 in / 1 out) 10/100Base T Ethernet
EMI / RFI AC Noise Suppression
Yes

PHYSICAL
Included Mounting Accessory Description
4 post rackmount installation accessories included
Installation Form Factors Supported
with Optional Accessories
2 post rackmount(2POSTRMKITWM) Wallmount(2POSTRMKITWM) Tower(2-9USTAND)
Primary Form Factor
Rackmount
Cooling Method
Fan
UPS Housing Material
Steel

ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)
256
AC Economy Mode BTU / Hr. (Full Load)
173
Battery Mode BTU / Hr. (Full Load)
439
AC Economy Mode Efficiency Rating (100% Load)
93%
Operating Elevation (ft.)
0-3000m / 0-10,000 ft.
Audible Noise
45 dBA at 1m front side
Operating Elevation (msnm)
0 - 3000 m

COMMUNICATIONS
Communications Interface
USB (HID enabled) DB9 Serial Contact closure EPO (emergency power off) Slot for SNMP/Web interface
Network Management Cards
SNMPWEBCARD TLNETCARD WEBCARDLX MODBUSCARD
Network Monitoring Port Description
Supports detailed monitoring of UPS and site power conditions DB9 port supports RS232 and contact closure communications
PowerAlert Software
For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable
USB and DB9 cabling included
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER
Transfer Time
Zero (0 milliseconds) in double-conversion mode 4 milliseconds economy mode
Low Voltage Transfer to Battery Power (Setpoint)
100V at full load (90V full load at 100V nominal setting) 70V at 70% load 55V at 33% load
High Voltage Transfer to Battery Power (Setpoint)
150

SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
High Availability UPS Features
Automatic inverter bypass Hot swappable batteries
Green Energy-Saving Features
High efficiency economy mode operation Individually controllable load banks Schedulable daily hours of economy mode operation

CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA) Tested to CSA (Canada) Meets FCC Part 15 Category B (EMI) ROHS (Restriction of Hazardous Substances)

Item Dimension (L inchxW inchxH inch)
20 x 24 x 9

Weight
48.40lb

Warranty Information
2-year limited warranty





















































































































































































  • Manufacturer:
  • Condition:
  • Weight:
  • Dimensions:
  • Updated:
  • Added:
  • Tripp Lite
  • New
  • 48.40lbs
  • 24 X 10 X 20
  • Apr 09, 2024
  • Dec 03, 2021

Request For Quote.


Tripp SU750RTXLCD2U Ups Smart Online 750va 675w Rackmount 100v-120v Lcd Usb Db9 2urm Rt - 750 Va-675 W - 127 V Ac, 127 V Ac - 4.30 Minute Stand-by Time - 2u Tower-rack Mountable - 6 X Nema 5-15r

Write a Review