OPTI-UPS UPS CS385B AUTOMATIC VOLTAGE REGULATOR AVR 385VA RETAIL CLEVER SERIES
Fully digitized microprocessor control. Energy saving (UPS sleep mode ). 50/60Hz frequency auto sensing. Buzzer can be muted by pressing "ON/OFF"button. Single PCB with reliable design. Clear LED alarms. Cold start (DC power on). Short circuit and overload protection. Advanced battery management (ABM). Automatic diagnostics battery check. Surge protection of all outlets. EMI/RFI noise filter. -------------------------
VENDOR: Opti-UPS
MPN: CS385B
UPC: 766908426662
KEY FEATURES PRODUCT TYPE - UPS CONNECTIVITY - NEMA 5-15R DETAIL SPECIFICATIONS
OUTPUT
UPS Capacity - 385VA
No. of Sockets - NEMA 5-15R, UPS x 2, Bypass x 2
Voltage (on battery) - Simulated sine wave at 100V / 115V / 220V /␘V < +/- 5% AVR controlled by PWM
Frequency (on battery) - 50 or 60Hz +/- 0.3 Hz
Transfer Time - < 10 milliseconds, including detection time
INPUT
Voltage (single phase) - 100V +/- 20%, 110V +/- 25% , 220V / 230V /␘V, 170V-280 at line input
Frequency - 50 or 60 Hz +/- 10% (auto sensing)
PROTECTION
Unit Input - Circuit breaker for overload and short circuit protection
Overload Protection - UPS Automatic shutdown if overload exceeds⎑% of nominal at 20 seconds, 120% at 10 seconds, 130% at 3 seconds
Short Circuit - UPS output cut off immediately
Spike Protection - 460 joules, 2ms
BATTERY
Type - Sealed, maintenance-free lead acid batteries with 3-5 years typical life time
Typical Recharge Time (to 90% of full capacity) - 6 hours
Back-up Time / PC with 15 LCD - 8 - 12 minutes
Protection - Automatic self- test, Over discharge protection, short circuit protection by fuse
PHYSICAL
Net Weight kg (lbs) - 1.6 (3.52)
Dimension WxDxH - 95 x 95 x 158 mm (3.74 x 3.74 x 6.22 inches)
INTERFACE
Dry Contact (option) - Sends battery low and power failure signals, and receives shutdown signal from computer
USB (option) - Detects power failure battery low, Schedules UPS ON / OFF, displays AC input / output power status
ALARM
Battery Backup - Short beeping sound every 4 seconds (Buzzer can be muted by pressing main switch button)
Battery Low - Rapid beeping sound every seconds
UPS Works at Full Load - Long continuous beeping sound every 4 second
Overload - Continuous beeping sound
ENVIRONMENT
Ambient Operation - 3,500 meters max elevation, 0-95% humidity (No-condensing water),0-40 deg C